Overview
EKA is a dealer and supplier of Mitsubishi Low-Voltage Switchgear in India. We supply Mitsubishi Low-Voltage Switchgear to customers in Chennai, Bangalore, Pune, Mumbai, Ahmedabad, Hyderabad, Delhi and other locations across India — share a part number or nameplate for price and availability.
Low Voltage Mitsubishi Switchgear
Low-voltage Switchgear Type AL-P
Highlights
- Heat stress analysis of the switchgear structure has led to a heat-resistant design in which circuit breakers up to 5000A are self-cooled (i.e.cooling fans not required).
- All components, such as current transformers, voltage transformers, relays and meters, are made of the highest quality materials.
- AL-P low-voltage switchgear are designed with the benefit of Mitsubishi's vast switchgear and circuit breaker production experience of in excess of one hundred thousand panels over last 50 years.
- The reduced number of parts reduce the chance of failure.
- Partitions between compartments and an automatic shutter system completely isolate live parts.
- The pressure relief device which is installed optionally releases hot gas upwards in the event of an internal arc fault for operator's safety.
- Control switches are installed at a height appropriate for easy viewing and operation.
- Installation and testing duration are considerably reduced as the switchgear is tested and adjusted in the factory and then delivered as a complete unit.
- Panels with main circuit and control cable entry from either top or bottom are available.
- The AL-P is readily combined with Mitsubishi Electric‘s Motor Control Center (MCC). The combined arrangement has advantages such as compact size and a simplified overall structure. As the MCC utilizes a double-front design, a larger number of motor starter units can also be accommodated. The AL-P is the perfect complement for Mitsubishi's MCCs. (Further information regarding Mitsubishi's MCCs can be found in a separate publication.)
Specifications
- Standard - IEC 60439-1 Low-voltage switchgear and controlgear assemblies
- Rated insulation voltage - 1000VAC
- Rated voltage - 690VAC
- System - 3φ3W / 3φ4W (4P ACB or 3P ACB with removable link) N Phase bus is half capacity.
- Rated busbar current (Horizontal) - 630-5000A
- Rated frequency - 50/60Hz
- Short-time withstand current (Horizontal bus) - 50, 65, 75, 85, 100kA 1-3s
- Withstand voltage - Main circuit 3500V
- Control - 1500V
Need Low-Voltage Switchgear in a hurry?