Skip to content
Industrial automation products & sparesPan-India supply from Chennai

Mitsubishi Electric · Medium-Voltage Switchgear

Mitsubishi Medium-Voltage Switchgear Supplier in India

  • Part-number enquiries
  • Replacement & obsolete parts
  • Multi-line BOM quotes
  • Pan-India supply from Chennai
Mitsubishi Medium-Voltage Switchgear – 7.2/12/15kV Metal-enclosed Switchgear Type MS-E

Have a part number?

Enter the model or order code and we will check price and availability.

Overview

EKA is a dealer and supplier of Mitsubishi Medium-Voltage Switchgear in India. We supply Mitsubishi Medium-Voltage Switchgear to customers in Chennai, Bangalore, Pune, Mumbai, Ahmedabad, Hyderabad, Delhi and other locations across India — share a part number or nameplate for price and availability.

Medium Voltage Mitsubishi Switchgear

7.2/12/15kV Metal-enclosed Switchgear Type MS-E

GM-SG air-insulated, non-arc-resistant, metal-clad, 5 kV-27 kV switchgear

Highlights

  • Type testing of the MS-E was performed by an independent external testing and certification authority, KEMA, in the Netherlands.
  • MS-E is designed with the benefit of Mitsubishi's vast medium voltage panels production experience of hundreds of thousands of panels over the last almost 60 years.
  • All components, such as current transformers, voltage transformers and multi-function relays are made of the highest quality materials.
  • Heat stress analysis of the switchgear structure has led to a heat-resistant design in which circuit breakers up to 3150 A are self-cooled (i.e. cooling fans not required).
  • The reduced number of parts reduces the chance of failure.
  • Partitions between compartments and an automatic shutter system (for withdrawable equipment primary junctions) completely isolate live parts.
  • Safe operation and maintenance is ensured with the adoption of comprehensive interlocking mechanisms.
  • In the event of an internal arc fault, the MS-E is designed to withstand the huge pressure and burning effect of the arc. (Relief flaps located on top of the panel open to limit pressure.)
  • Installation and testing duration are considerably reduced as the panel is tested and adjusted in the factory and then delivered as a complete unit.
  • Panels with main circuit and control cable entry from either the top or bottom are available.

Specifications

  • Standard - IEC 62271-200
  • Rated voltage(kV) - 7.2/12/15
  • Rated frequency(Hz) - 50/60
  • Rated nominal current (A) - 630, 1250, 2000, 3150, 4000* (4000A with force cooling)
  • Rated power freq. voltage(kV) - 20/28/36-1min
  • Rated lightning impulse voltage(kV) - 60/75/95
  • Rated short-time withstand current (kA) - 25/31.5/40
  • Rated duration of short-time current (sec) - 3
  • Dimension WxDxH[mm] (for 630A feeder) - 800 x 1500 x 2600
Mitsubishi Medium-Voltage Switchgear – 7.2/12kV 2 Tier Metal-enclosed Switchgear Type MS-E

7.2/12kV 2 Tier Metal-enclosed Switchgear Type MS-E

Highlights

  • MS-E is in the highest operating continuity loss category, securing safety at the time of service and maintenance work, and a protective plate grade (LSC2B-PM class).
  • MS-E features mechanical and electro-mechanical interlock conditions complying with IEC62271-200.
  • To facilitate smooth grounding of the main circuit during service and maintenance work, the grounding switch is located on the main circuit busbar and cable draw-in circuit.
  • The MS-E can be transported with the drawer-type VPR/VMC*1 /VT units installed in the panel.
  • Sufficient space for cable termination has been secured in the main circuit cable compartment.
  • Inter-panel connection of the main circuit horizontal busbar is done by installing a connection conductor.
  • Inter-panel connection of the connection conductor is done using the bolts on either side of the connection conductor.

The MS-E design satisfies the internal arc protection classification (IAC) of AFLR.

  • The “A” of AFLR restricts access to authorized personnel only, while the “FLR” means safety is required up to a height of two meters in the front (F), sides (L), and rear (R).

The interior panel drawer-type VPR/VMC/VT units can be moved from the disconnected position (test position) to the operating position without opening the panel (from outside of the panel).

  • (Drawer-type VPR/VMC units have a mechanical interlock preventing open/close o

The drawer-type VPR/VMC units built into the MS-E offer the highest mechanical durability and electronic durability classifications, and comply with IEC international standards.

  • VPR: Mechanical (M2), Electrical (E1, E2)
  • VMC: Mechanical (25 and 2.50 mill times), Electrical (AC-3)
  • The VPR of the MS-E provides excellent current isolation performance thanks to combining a vacuum interrupter using spiral contacts manufactured using a new material and an electric control mechanism with a solid track record spanning many years.
  • The operability, serviceability and maintainability of machinery have been improved by arranging components used frequently, such as the drawer-type devices (e.g., VPR/VMC/VT units), grounding switchgear, and monitor and control devices, in a compartment on the front of the panel front, and protective devices (e.g., CT, ZCT, LA, and CR) and the main circuit cable in a compartment on the back of the panel.
  • The MS-E can operate up to a maximum busbar current rating of 3,150A using natural ventilation.
  • The incorporation of a (FBC) epoxy resin coating (FBC) having a long history of good performance when used between main circuit phases and ground connections, provides even stronger insulation for the live sections of the main circuit. (optional)

Specifications

  • Rated voltage(kV) - 7.2/12
  • Rated frequency(Hz) - 50/60
  • Rated nominal current (A) - 630, 1250, 2000, 3150
  • Rated power freq. voltage(kV) - 20/28-1min
  • Rated lightning impulse voltage(kV) - 60/75
  • Rated short-time withstand current (kA) - 25/31.5/40
  • Rated duration of short-time current (sec) - 3
  • Internal Arc Classification - AFLR 40kA/1.0sec
  • Dimension WxDxH[mm] (for 630A feeder) 800 x 2200 x 2600 (*235 for top air vent)

Need Medium-Voltage Switchgear in a hurry?

Send the exact order code (MLFB) or a nameplate photo and quantity for price and availability.

Next step

Get a quote for Mitsubishi Medium-Voltage Switchgear

EKA confirms the exact variant against your order code or nameplate before quoting.