SIEMENS CABLES IN INDIA

Leading distributor and dealer of Cables from Siemens in India

EKA supplies siemens cable solutions for industrial automation—covering network cabling, fieldbus wiring, PLC programming leads, and drive feedback connections. Our team helps you choose the correct item by verifying the part number (MLFB), connector type, required protocol, cable category, length, and installation condition—so you receive a compatible product the first time.

Call/WhatsApp: +91 90433 36700
Email: ekacncindia@gmail.com
Delivery: Chennai | Bengaluru | Pune | Mumbai | Ahmedabad | Hyderabad | Delhi | Pan-India shipping

Cable Types

Siemens cable families used in industrial automation are typically grouped into Industrial Ethernet/PROFINET, fiber-optic, and PROFIBUS cabling—plus related encoder and PLC communication leads.

Industrial Ethernet / PROFINET Copper Cables (Twisted Pair)

These siemens industrial ethernet cables support PROFINET/Industrial Ethernet communication between PLCs, switches, HMIs, and remote I/O. Selection depends on conductor count (2×2 vs 4×2), bandwidth requirement, connector type (RJ45/M12), and installation conditions.
  • IE FC TP cable 2 × 2 – FastConnect installation cable (4-wire), commonly used as an industrial siemens lan cable for standard copper network links.
  • IE FC TP cable 4 × 2 – FastConnect installation cable (8-wire), typically chosen when a siemens cat6a cable class requirement is specified for higher bandwidth networks.
  • IE TP cord – prefabricated patch cords for quick cabinet/device connections.
  • Pre-assembled IE connecting cables – ready-made connecting leads (M12/RJ45 combinations based on device ports).
  • Energy cables – auxiliary/power supply cables for industrial routing, including variants suited for moving/energy-chain environments and powering field devices where required.

Fiber-Optic Cables

Fiber is selected for longer distances, electrical isolation, and strong immunity to electromagnetic interference (EMI) in harsh industrial environments.
  • FC glass fiber-optic cables – FastConnect FO range for on-site assembly and industrial installation.
  • Glass fiber-optic cables – standard glass FO range for industrial networks.
  • POF & PCF fiber-optic cables – polymer fiber variants used in specific fiber applications.

PROFIBUS Cables (FastConnect)

These siemens profibus cables are used in PROFIBUS networks where the bus cable, connector type, and termination must match the installation. Many projects request Profibus Cable Siemens for replacements or expansions.
  • PROFIBUS FC installation cables – 2-wire FastConnect PROFIBUS bus cables used with PROFIBUS connector Siemens variants.
  • For correct planning, the PROFIBUS cable specification should align with the device requirements, shielding practice, and network layout.
MiTSUBISHI-CABLES-3

SIEMENS CABLES

SIEMENS CABLE IE FC TP 2 × 2 (FastConnect)

IE FC TP cable 2 × 2 is a 4-core Industrial Ethernet copper cable from the FastConnect family, typically used for Fast Ethernet / PROFINET (10/100Base-TX) networks. It is designed for quick, repeatable field installation with FastConnect components and supports reliable operation in industrial environments when the correct variant is chosen for the application.

Highlights

 4-core twisted-pair copper solution for Industrial Ethernet / PROFINET copper wiring

 FastConnect-ready built for faster onsite preparation with FC stripping/assembly workflow
 Cat5e class structured cabling level (for many variants)

 Shielded design with strong noise immunity (double-shield constructions used across variants)

 Meter marking on the sheath for easier cutting/length control

 Multiple variants for fixed, flexible, continuous movement, torsion/robot, food, marine, ground, and rail applications

 Approvals (UL/ETL, etc.) are available on specific variants (choose by requirement)

Variant selection

Variant selection

Siemens groups this family into variants suited for different mechanical stress and environments. Use the list below on your page so customers can self-identify what they need.

Common cable variants in the 2 × 2 family

 Standard / GP (Type A) – general fixed installations

 Robust standard (Type A) – tougher outer jacket for industrial wear
 Flexible (Type B) – for occasional movement/vibration

 Robust flexible (Type B) – flexible plus stronger jacket

 FRNC (Type B) – halogen-free option used in building/low-corrosion requirements

 Trailing cable (Type C) – for continuous bending in cable carriers (moving machine parts)

 Festoon cable – continuous movement in festoon/crane-style routing

 Torsion cable – continuous torsional stress applications

 Robot cable (Type R) – combined torsion + bending stresses typical in robot dress packs

 Food cable – for food & beverage environments

 Robust food cable – washdown/harsh cleaning use (variant dependent)

Marine cable – marine/offshore certified variants (as required)

 Ground cable – fixed burial/soil routing variants

Robust ground cable – added mechanical protection for harsh ground routing

 Train cable – railway-certified variant families (project dependent)

Applications

 PROFINET/Industrial Ethernet wiring between automation devices where 10/100 Mbps copper links are required

 Installations where fast, consistent FC termination saves time (panel builds, line expansions, quick replacements)

 Moving equipment applications when the correct Type B / Type C / Type R cable is selected (drag chain, torsion, robots, cranes)

 Special environments (food, marine/offshore, underground routing) using the relevant variant

SIEMENS CABLE IE FC TP cable 4 × 2

SIEMENS CABLE IE FC TP cable 4 × 2<br />

IE FC TP cable 4 × 2 is an 8-core FastConnect Industrial Ethernet copper cable built for higher-bandwidth cabling (Gigabit/10G-ready systems depending on the device setup). The family includes AWG22 / AWG24 / AWG26 variants and is commonly selected when an 8-wire Cat6A/Cat7 class network link is required in industrial automation.

Highlights

 8-core FastConnect installation cable for high-performance Industrial Ethernet cabling

 FastConnect stripping workflow supports quick preparation of jacket + shield using FC tools

IDC-style termination with compatible FastConnect outlets/plugs (connector depends on AWG and port type)

 Meets structured cabling classes typically associated with Cat6A and Cat7 (variant dependent)

 UL/ETL approvals are available on GP variants (choose by requirement)

 Meter markings on the sheath help with accurate length cutting and planning

Connection options

Selection depends on conductor size and the connection style required:

 AWG22: often used with an IE FC RJ45 modular outlet (patch-style installations)

 AWG24 / AWG26: often used for direct assembly with IE FC RJ45 plug 4×2, IE FC M12 plug PRO 4×2 (X-coded), or IE FC keystone RJ45 (device/port dependent)

Application

 Industrial Ethernet networks where 10/100/1000/10000 Mbps transmission is required (device and installation dependent)

 AWG22: often used with an IE FC RJ45 modular outlet (patch-style installations)

 Point-to-point cabling where an 8-core link is needed and fast field termination is preferred

 Installations that need consistent shielding/grounding practices across the network

SIEMENS CABLE – Energy cables

Siemens Energy Cables are used to deliver 24 V DC power and auxiliary signals to field devices in industrial networks—especially where equipment is installed outside the cabinet with IP65/67/69 protection. The range includes multiple conductor configurations (2-core, 4-core, 5-core) and also pre-assembled M12 power/control cables for faster installation.

Highlights

 Multiple performance options: 2-core / 4-core / 5-core versions for different power and signal needs

 Pre-assembled M12 power cables available for quick field connection (straight or angled versions)
 Industrial-grade construction suited for plant installation and routing

 Many variants available with UL/ETL approvals (depends on model)

 Meter markings on the outer sheath to simplify length measurement and cutting

 Versions suitable for tough environments; silicone-free options available for paint shop / automotive areas

SIEMENS CABLE – Pre-assembled IE Connecting Cables (M12 / RJ45)

Pre-assembled IE connecting cables are ready-to-use Industrial Ethernet leads with factory-fitted connectors. They are used to connect network devices quickly where you want a consistent installation without field termination. Depending on the device ports, cables are supplied with M12 or RJ45 ends and are suitable for data transmission and, where supported by the network devices, PoE.

Why these cables are used

 Faster installation (no onsite crimping/termination)

 Stable shielding contact and integrated strain relief (helps reduce intermittent faults)
 Wide choice of connector combinations, angles, and lengths (custom lengths available for selected variants)
Common options

M12 D-coded (4-pin) – typically used for 10/100 Mbps links for field devices with IP65/67 ports and compact installations:

 M12 ↔ M12 (straight 180° or angled 90° cable outlet)

 M12 ↔ RJ45 for linking field devices to cabinet equipment

 Rugged / washdown variants (IP69 options available, depending on model)

 Versions with push-pull connection system (depending on device and interface)

M12 X-coded (8-pin) – used for higher bandwidth links (device-dependent) for higher-performance Ethernet connections:

 M12 ↔ M12 (straight 180° or angled 90°)

 M12 ↔ RJ45 transition cables to connect IP65/67 devices to IP20 cabinet ports

RJ45 connections (cabinet / protected areas) for IP20/IP30 installations in panels and control cabinets:

 RJ45 ↔ RJ45 patch/connecting leads in multiple lengths

 2×2 and 4×2 variants chosen based on the bandwidth and device requirement

Interface transition adapter

Interface transition adapter

SIEMENS CABLE – FC glass fiber-optic cables

Highlights

FastConnect standard fiber-optic cable for use in optical Industrial Ethernet, PROFINET and PROFIBUS networks
For all users who want to install and assemble the glass fiber-optic cables themselves over longer distances on site for office or industrial applications
Simple FastConnect LC and ST/BFOC connector assembly on site
Rugged design for industrial applications both indoors and outdoors
High interference immunity as not sensitive to electromagnetic interference
Extensive range of UL approvals
Avoidance of excessive cable lengths in the control cabinet, as the fiber-optic cables can be assembled to the right length on site
Easy installation of cables in buildings, as cables can be pulled in without connectors attached
Simple extension of installed glass fiber-optic cables via LC and ST/BFOC couplers
Devices with different connection systems (LC or ST/BFOC) can easily be connected to one another using self-assembled adapter cables
Electrical isolation of Industrial Ethernet/PROFINET/PROFIBUS devices
Unaffected by electromagnetic interference
Tap-proof: no radiation from cable

Applications

SIMATIC NET FastConnect glass fiber-optic cables are used to construct optical indoor and outdoor Industrial Ethernet/PROFINET and PROFIBUS networks. Devices with integral optical interface (LC or ST/BFOC connection technology) include optical link modules (OLM) and SCALANCE X Industrial Ethernet switches, for example.
FastConnect glass fiber-optic cables are to be assembled on site using FastConnect FC LC or FC ST/BFOC connectors. Two FC FO assembly cases are available for this purpose. They enable stripping and “cleaving” of the fiber in the assembled connector, as is familiar from PCF fiber-optic cables. For ST/BFOC connectors, the ST/BFOC coupler can be used to extend existing lines

PRODUCTS

FAQ – Siemens Cables

Where can I buy Siemens cables in India?

EKA is a dealer and distributor of Siemens cables in India, supplying cable variants for industrial networking, PLC connectivity, and drive/encoder applications. We support pan-India dispatch and help match the correct cable based on part number (MLFB), port type, and installation requirement.

Which siemens industrial ethernet cables are used for PROFINET?

PROFINET over copper is selected by device port (RJ45 or M12), required speed, and environment (fixed, moving, harsh area). Sharing switch/PLC port photos makes matching quicker.

What is the right siemens lan cable for factory networks?

For industrial LAN, selection depends on whether you need 100 Mbps or higher bandwidth, plus the connector style (RJ45 vs M12) and shielding requirement for noisy shopfloor areas.

When should I choose a siemens cat6a cable?

Cat6A-class cabling is typically chosen when the network is designed for higher throughput and your devices/ports support it. If you’re unsure, share your switch model and port type.

Which siemens profibus cables should I use for an existing PROFIBUS line?

Match the bus cable type to the existing installation and ensure the connector and termination style are correct. For retrofit jobs, sharing the old cable marking/connector photo helps prevent mismatch.

Which PROFIBUS connector Siemens type do I need (straight or angled)?

It depends on panel space, cable entry direction, whether a PG/diagnostic port is needed, and how termination is handled. A photo of the current connector or device port is the fastest way to confirm.

What details matter in a PROFIBUS cable specification?

The key items are shielding/grounding practice, correct termination, network layout (line length and number of nodes), and routing conditions (drag chain, outdoor, high EMI). Share your layout and we’ll recommend a suitable option.

Do you supply Profibus Cable Siemens for replacement and expansion?

Yes—replacement projects usually require matching the existing connector style and ensuring the bus cable and termination method stay consistent across the segment.

Which siemens encoder cable should I order for a drive or motor?

Encoder/feedback cables must match the drive series, connector type (drive side + motor side), and required length. Send photos of both connectors and the drive model to confirm the correct cable.

What is a siemens communication cable used for?

It’s used to connect PLC/PG/HMI systems depending on the interface (PROFINET, PROFIBUS/MPI, or other Siemens communication ports). The correct choice depends on the PLC model and the port you’re using.

Which siemens s7 cable is used for programming or commissioning?

That depends on the CPU family and interface (Ethernet/PROFINET vs MPI/PROFIBUS). Share the CPU model and port type and we’ll match the correct lead/adapter.

What is the correct siemens s7 300 cable for S7-300 PLCs?

S7-300 setups commonly use MPI/PROFIBUS-based programming/communication depending on the CPU and your PG/laptop method. A CPU model photo helps confirm the compatible cable.

What affects siemens mpi cable price?

Price depends on the exact adapter/lead type, cable length, and compatibility requirements (USB/PC adapter type, MPI/DP support, and genuine part vs equivalent). Share your CPU model and connection method for an accurate quote.

Do you supply a single siemens cable that covers both data and power?

For Industrial Ethernet, some installations use PoE (power over Ethernet) where supported by devices, but it still depends on equipment capability and cable/connector variant. Share device models and we’ll advise the correct approach.